www.hypergienic.co.uk

Standard Features...


Body can be manufactured with flanged or coupling inlet and outlets

 

End Covers with dome nut fixings and pocket purge ports

 

Open fixed vane Stainless Steel 316L Rotor with 8 sealed scalloped, chamfered vanes

 

Sliding ‘Trombone’ support rails fitted with linear bearings, allow rapid scratch free access for cleaning

 

Pharmaceutical standard seals provide secure joints between body, end covers and inlet connections

 

0.5Ra (240 Grit) polish finish internal and external

 

Homogeneous and hygienic construction, Crack and Crevice free design.

 

All surfaces are self-draining to avoid fluid retention after valve ‘wash-down’

 

FDA approved materials

 

Fully tested & certified against 10 Barg internal explosion and flame containment

 

Special multi-function shaft seal design including FDA double lip seal assembly and air purge connection (see options for further functions available)

 

Fixed speed direct drive geared motor unit 17.5 RPM. Standard Aluminium framed Spaggiari drive, suitable for non-hazardous/non-wash down applications

 

Sealed bearing assembly with FDA grease

 

Rotation sensor with multi flag target aligned to pocket position

 

Earth brush to ensure electrical continuity between rotor and body

 

Standard extractor tool and stainless steel terminal box

 

Hydrostatic testing to 13 Barg to certify 10barg

 

 

Standard documentation included (2 sets):-

 

Manufacturing Plan

 

General Arrangement Drawing (Planning-in Drawing)

 

Electrical Circuit Drawing

 

Installation, Operation and Maintenance Manual, including priced spares list

 

Hydrostatic Test certificate

 

Factory Acceptance Test

 

Lubrication Schedule

 

Basic Material certification (i.e. General certificate of conformity to confirm specification of materials used – See Options for full material / mill certificates)

 

Surface Finish Certification (i.e. In-house test to confirm surface finish equal or better than that specified)

 

Basic Weld and Welder Qualifications (i.e. Standard conformity letter from sub-contractors –

See Options for full named welder certificates)

Copy of Explosion Testing Certificate

 

Certificate of Incorporation